Voltage measurement ranges |
0-50mV, 0-100mV, 0-500mV, 0-1V, 0-5V
±25mV, ±50mV, ±100mV, ±500mV, ±2.5V
|
|
Current measurement ranges |
0-20mA (with 249 ohm shunt) 4-20mA (with 309 ohm shunt) |
|
Resolution |
12 bit |
|
Accuracy |
±2 LSB |
|
Clock Accuracy |
±1 minute/month |
|
Measurement interval |
|
Sensor power up settling delay |
1 to 255ms or always on |
|
Sensor voltage level |
User adjustable from 3V to Vin-1V
Factory set to 5V nominal |
|
I/O control data format |
ASCII text string |
|
Record data format |
Comma delimited ASCII string |
|
I/O type rate |
RS232 @ 9600 baud |
|
Optional memory size |
128K, 256K or 1M record sets |
|
Remote control facilities using supplied MultiLog software |
Set measurement range for each channel
Set sensor settling time for each channel
Set logging interval
Select logging destination (I/O port or memory*)
Set clock time
Read channel data and settings
Read clock time
Download/reset/erase memory*
*When memory module is fitted
|
|
Supply voltage (Vin) |
9-15V or can be powered from RS232 port when sensors are self powered
|
|
Current consumption |
12mA (excluding sensors)
|
|
Data I/O connector |
9 way female D-type
|
|
Analog input/sensor supply connector |
Standard 25 way male D-type
Optional Terminal block adapter PCB
|
|
Construction |
100 x 160mm Eurocard housed within an IP54 rated anodised aluminium case
|
|
Housing size |
103 x 175 x 31 (W x L x Hmm)
Terminal block adapter increases height to 53mm
|
|
Operating temperature |
Standard -10° to +50°C
Optional - 40° to +80°C
|